Part of the Environment & Climate suite · 27 calculators

Hydroelectric Power Calculator

The power a stream or dam can generate from its head and flow, and what that comes to over a year.

Water falling through a head H at a flow Q carries ρ·g·Q·H watts — 9.

Results update as you type
Results
Rated power
417 kW
Gross hydraulic power
Annual energy
Households supplied
Power per m³/s of flow
Reviewed September 2026. Physics and published emission factors: the same arithmetic wherever you are, though grids and supply chains differ. UK grid intensity has fallen by more than half since 2013, so older figures overstate electricity emissions.
No account required · Google Analytics off unless allowedCalculator arithmetic runs in your browserResults update as you type
All calculations run 100% in your browser. The calculator code does not submit your figures to GlobalCalc to obtain a result.
About hydroelectric power

How the hydroelectric power calculator works

Water falling through a head H at a flow Q carries ρ·g·Q·H watts — 9.81 kW for every cubic metre per second falling one metre — and a turbine and generator keep 70–90% of it. A plant rarely runs flat out all year, so annual energy is rated power × hours × capacity factor. The household figure is an input, because an average home’s consumption differs by country.

Formula: P = ρ · g · Q · H · η; annual energy = P × 8,760 h × capacity factor

Worked examples

InputsRated powerNote
25 m head, 2 m³/s, 85% efficient417 kW417 kW
80 ft head, 70 cfs403 kW403 kW
A micro-hydro creek: 10 m, 0.05 m³/s3 kW3.4 kW

Frequently asked questions

What head and flow does a home micro-hydro need?

A few kilowatts needs either a big drop or a lot of water: 10 m of head with 50 L/s gives about 3.5 kW at 70% efficiency. Under 1 kW is still worthwhile because it runs day and night.

What efficiency should I use?

Large turbines reach 90% or more; small Pelton and crossflow units 60–80% including the generator. Friction in the penstock reduces the usable head further — enter net head if you know it.

What is capacity factor?

The share of the year the plant produces its rated output. A run-of-river plant with seasonal flows might average 40–60%, a dam with storage higher. It converts rated kilowatts into a year’s kilowatt-hours.

Why is household consumption an input?

Because it differs several-fold between countries — roughly 2,700 kWh a year in the UK, 5,500 in Australia, 10,500 in the US — so any single baked figure would be wrong for two of the three.

Where these figures come from

Last checked: September 2026. Factors are taken from published government and peer-reviewed sources, each named on the page with its year.