Occupant Load Calculator

The occupant load of a floor from its area and use — the number every fire and egress calculation starts from — and the total exit width and number of exits it needs.

Codes assign each use a floor area per person: about 10 m² for offices, 1 to 2 for assembly, 30 for warehouses.

Results update as you type
Results
Occupant load
140
Total exit width required (mm)
Exits required
Width per exit if split evenly (mm)
Standard 900 mm door leaves needed
Load if the floor were assembly use (1.5 m²/person)
Occupants per exit
Reviewed September 2026. Building physics and geometry are the same everywhere; only the code thresholds move. Approved Documents B (fire), K (stairs), L (energy) and M (access) carry the thresholds a design is checked against.
No account required · Google Analytics off unless allowedCalculator arithmetic runs in your browserResults update as you type
All calculations run 100% in your browser. The calculator code does not submit your figures to GlobalCalc to obtain a result.
About occupant load

How the occupant load calculator works

Codes assign each use a floor area per person: about 10 m² for offices, 1 to 2 for assembly, 30 for warehouses. Divide the area by that factor and you have the occupant load the exits must serve.

Exit width follows: a set number of millimetres per person, with a minimum count of exits above a load threshold. The factors here are common defaults and inputs, because every code sets its own.

Formula: occupants = area / factor; exit width = occupants × mm per person

Worked examples

InputsOccupant loadNote
A 1,400 m² office floor140140 people, two exits
A function room267267 people from a small floor
A warehouse134few people, wide floor

Frequently asked questions

What is occupant load?

The number of people a space is designed to hold for fire and egress purposes — floor area divided by a factor set by the use. It is often higher than the number who will ever be there.

What area per person applies?

About 10 m² for offices, 1 to 2 for assembly and bars, 3 for shops, 30 for storage. Every code publishes its own table; the default here is the office figure.

How much exit width per person?

Ten millimetres is a common figure for a level exit; stairs need more. Codes also set minimum door and corridor widths regardless of load.

When are two exits required?

Above a load threshold — often 50 — or above a travel distance. Larger loads need three or four. The count here is a common default, not your code.

Can I reduce the occupant load?

By declaring a lower design occupancy and posting it, in some codes. The exits still need to serve whoever actually turns up.

Where these figures come from

Last checked: September 2026. Formulas are the standard building-science and code relationships; default thresholds are common international values and should be replaced with the ones in your code.