Daylight Factor Calculator

The average daylight factor of a room — the share of outdoor light that reaches the inside — from glazing area, glass transmittance, the room's surfaces and how much sky the window sees.

The standard estimate is DF = T × Aw × θ / (A × (1 − R²)): glass transmittance, window area, the angle of visible sky, divided by total room surface area and a term for how reflective the room is.

Results update as you type
Results
Average daylight factor
2.31%
Total room surface area (m²)
Reading
Glazing needed for 2% (m²)
Glazing needed for 5% (m²)
Interior light under a 10,000 lux overcast sky (lux)
Daylight factor with 0.7 reflectance
Reviewed September 2026. Building physics and geometry are the same everywhere; only the code thresholds move. The IBC is adopted with local amendments; the authority having jurisdiction decides compliance.
No account required · Google Analytics off unless allowedCalculator arithmetic runs in your browserResults update as you type
All calculations run 100% in your browser. The calculator code does not submit your figures to GlobalCalc to obtain a result.
About daylight factor

How the daylight factor calculator works

The standard estimate is DF = T × Aw × θ / (A × (1 − R²)): glass transmittance, window area, the angle of visible sky, divided by total room surface area and a term for how reflective the room is. It is the formula in every daylight guide and it is accurate to within a factor that does not matter at sketch stage.

Two per cent is the usual minimum for a room to feel daylit; five per cent and the lights stay off on most days. Above that, glare and heat gain start to matter more than daylight.

Formula: DF = T × A_window × θ / (A_total × (1 − R²))

Worked examples

InputsAverage daylight factorNote
A 27 m² room with 4.2 m² of glass2.31%about 2.4% — daylit
An obstructed window1.07%dim
A bright room4.96%nearly 5%

Frequently asked questions

What is a daylight factor?

The ratio of light inside to light outside under an overcast sky, as a percentage. It describes the room, not the weather.

What daylight factor is enough?

Two per cent feels daylit; five keeps the lights off on most days. Living rooms and offices target 2 to 5, kitchens and studios higher.

What is the visible sky angle?

The vertical angle of unobstructed sky seen from the window center. An open site gives 80 to 90; a window facing a building across a narrow street may see 30.

Why does surface reflectance matter?

Because most daylight in a room has bounced at least once. White walls and a pale floor can raize the factor by a third for the same glass.

Is this a compliance calculation?

It is the sketch-stage estimate the compliance methods refine. Climate-based daylight modelling is what a rating scheme will ask for.

Where these figures come from

Last checked: September 2026. Formulas are the standard building-science and code relationships; default thresholds are common international values and should be replaced with the ones in your code.