Furnace and Heater Size Calculator

A first estimate of the heating output a home needs — from its floor area, the climate's heating factor, the ceiling height and the insulation standard — in kilowatts and BTU per hour, with a margin, and the furnace or heat-pump size to look for.

Heating load scales with floor area and the climate: a mild climate needs about 40 W per square metre of floor for a well-built house, a cold one 80 to 100.

Results update as you type
Results
Furnace output to look for
10 kW (34000 BTU/h)
Estimated heat load (kW)
Estimated heat load (BTU/h)
With margin (kW)
With margin (BTU/h)
Load per unit of floor area (W)
Adjustments applied
Reading
Reviewed September 2026. Geometry is the same everywhere; units, bag sizes and sheet sizes follow your region and can be switched. Stair, ramp and structural rules are in the NCC.
No account required · Google Analytics off unless allowedCalculator arithmetic runs in your browserResults update as you type
All calculations run 100% in your browser. The calculator code does not submit your figures to GlobalCalc to obtain a result.
About furnace and heater size

How the furnace and heater size calculator works

Heating load scales with floor area and the climate: a mild climate needs about 40 W per square metre of floor for a well-built house, a cold one 80 to 100. Taller rooms hold more air and add load; good insulation and glazing take it away. A furnace should be sized close to the load with a modest margin — an oversized one short-cycles, wastes fuel and controls temperature badly. A full Manual J or equivalent calculation replaces this; it is the right ballpark for a quote.

Formula: load = area × factor × ceiling adjustment × insulation adjustment; furnace = load × (1 + margin); 1 kW = 3,412 BTU/h

Worked examples

InputsFurnace output to look forNote
A typical home10 kW (34000 BTU/h)a whole-house system
Well insulated8.5 kW (29000 BTU/h)15% smaller
A cold climate22.3 kW (76000 BTU/h)a large system

Frequently asked questions

How many kilowatts does a house need to heat?

Roughly 40 to 100 W per square metre of floor depending on climate and construction — 7 to 18 kW for a 180 m² home. In BTU per hour that is 25,000 to 60,000.

What heating factor should I use?

Mild coastal climates 35 to 50 W/m², temperate 55 to 75, cold continental 80 to 110. Older, leakier houses sit at the top of each range; the insulation setting adjusts within it.

Why not oversize to be safe?

An oversized furnace reaches temperature and shuts off within minutes, repeatedly — short cycling — which wastes fuel, wears the unit and leaves rooms uneven. Ten to twenty per cent margin is plenty.

Does this size a heat pump?