Window Heat Loss Calculator

The heat that flows through a window or door — from its area, its U-value and the temperature difference across it — in watts and over a heating season, with the energy cost and what upgrading to a lower U-value would save.

Heat flow through a window is U-value times area times the temperature difference: a 2 m² single-glazed window at U 5.

Results update as you type
Results
Heat loss at the design difference (W)
776
Glazed area (m²)
Loss per window (W)
Heat lost per heating season (kWh)
Cost per season
Season loss after the upgrade (kWh)
Saving per season
Payback on the upgrade (years)
Reading
Reviewed September 2026. Geometry is the same everywhere; units, bag sizes and sheet sizes follow your region and can be switched. Stair and ramp rules follow the IRC and ADA.
No account required · Google Analytics off unless allowedCalculator arithmetic runs in your browserResults update as you type
All calculations run 100% in your browser. The calculator code does not submit your figures to GlobalCalc to obtain a result.
About window heat loss

How the window heat loss calculator works

Heat flow through a window is U-value times area times the temperature difference: a 2 m² single-glazed window at U 5.8 loses about 230 W on a day 20 °C colder outside than in. Over a heating season of degree-hours that is kilowatt-hours, and at your tariff a cost. Double glazing at U 2.8 halves it; a good low-emissivity unit at 1.4 cuts it by three quarters, which is the arithmetic behind the payback.

Formula: Q = U × A × ΔT; season kWh = U × A × degree-hours / 1000

Worked examples

InputsHeat loss at the design difference (W)Note
Four single-glazed windows776hundreds of watts
Already double glazed375half the loss
A colder climate1,293a faster payback

Frequently asked questions

What is a U-value?

The heat flow through a square meter of the element per degree of temperature difference, in W/m²K. Lower is better: single glazing about 5.8, standard double 2.8, low-e argon-filled double 1.4, triple under 1.

What are degree-hours?

The sum over the heating season of the temperature difference between inside and outside, hour by hour. Mild climates have 20,000 to 40,000 °C·h; cold ones 60,000 to 100,000. Degree-days times 24 gives the same figure.

What does the heat cost?

The price of delivered heat — electricity at its tariff divided by a heat pump's coefficient of performance, gas at its price divided by the boiler's efficiency. The default is a typical blended figure.

Is the payback realistic?

For single-to-double it is usually ten to twenty years on heat alone; comfort, noize and condensation are the reasons people actually do it. For double-to-triple it is longer still.

What about frames and doors?

A window's whole-unit U-value includes the frame, and doors are the same sum with their own U-value. Enter the unit figure the maker quotes, not the glass alone.